Plain Track

Continuous Rating:
100 Amperes - 600 Volts A.C. - 250 Volts D.C.

Intermittent Rating:
150 Amperes - 600 Volts A.C. - 250 Volts D.C. (1 minute off, 1 minute on)

Note: 10 feet is standard length. Shorter lengths furnished on special order; minimum length 20 inches.

Click HERE to view all plain track sections.

Feedrail®'100' Bus Bar Arrangement

Door Track

Door track sections are identical to plain track sections except with the addition of two hinged doors in the bottom for the insertion and removal of trolleys. When closed, the doors are securely locked and accurately aligned with the rest of the track to form an uninterrupted runway for the trolleys.

Hinged doors are easy to open or close. No tools are required. Pressing pins together against spring pressure disengages locking bolts. Door openings are polarized so trolleys can be inserted only one way.

Click HERE to view all door track sections.

Curved Track

Curved sections are of the same general specifications as plain track. All standard curved track sections are full 90° curves and have an additional 4" of straight track on each end for coupling. Special sections with different degrees of arc and radius from those listed below can be furnished to order. Minimum radius, 2'6". Maximum length per single curved section is 12'6". 90° curves.

Click HERE to view all curved track sections.

Note: Sections complete with Bus Bars

Sectionalizing Track

Sectionalizing Track sections isolate portions of a track run. They are the same as Plain Track sections except at the center of the track each bus bar is interrupted by an air gap. The bus bars are so formed and positioned by a special insulator that all trolleys smoothly cross the air gap while maintaining electrical continuity. The circuits on both sides of the gap are momentarily tied together through the trolley contacts as the trolley passses the air gap.

Special sectionalizing Track sections are made that do interrupt the current to the trolley. When used, there require two electrically connected trolleys to maintain current through the trolley at all times. They must not be used as a circuit interrupting device.

Click HERE to view all sectionalizing track sections.

Note: Sections complete with Bus Bars

Expansion Track

Continuous Rating:
100 Amperes - 600 Volts A.C. - 250 Volts D.C.

Intermittent Rating:
150 Amperes - 600 Volts A.C. - 250 Volts D.C. (1 minute off, 1 minute on)

Click HERE to view all expansion track sections.

Transfer Sections

Transfer sections are similar to plain track sections, except have one or two ends flared for use at points of transfer on slide switches, turn-tables, etc. (transfer track sections for use on turn-tables, or slide switches ar enot stock items but are manufactured specifically to meet given dimensions). A nose insulator at the transfer point serves as a guide for the proper entrance of the trolley. Curved transfer sections with one or both ends flared, with or without doors, and with feed-in boxes installed can be furnished on special order.

Click HERE to view all transfer track sections.

Notes: When ordering transfer sections with one end flared for connection to existing track, indicate whether bus bars are to connected to plain or offset bus bar ends as shown below.

Where motor propelled hoists are used on runs which include transfer points, it is necessary to use Duplex Transfer Type Trolleys. Current is maintained to one trolley while the other crosses the transfer gap.